When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Anti-Fungal Susceptibility

Test Codes

EPIC: LAB6523, SOFT: XFNGS

Instructions

  • Please indicate all antifungal agents patient is receiving at time of specimen collection.
  • Contact the Sendout Laboratory for more information (248-551-9045).

Specimen Collection Criteria

Collect: Isolated organism in pure culture.

Physician Office/Draw Specimen Preparation

Maintain specimen at room temperature (20-26°C or 68-78.8°F) prior to transport.

Preparation for Courier Transport

Transport: Pure culture isolate, at room temperature (20-26°C or 68-78.8°F).

Rejection Criteria

  • Specimens not collected and processed as indicated.

In-Lab Processing

Maintain specimen at room temperature (20-26°C or 68-78.8°F) prior to transport.

Transport: Pure culture isolate, at room temperature (20-26°C or 68-78.8°F). 

Storage

Specimen Stability for Testing:

Isolates should remain at room temperature (20-26°C or 68-78.8°F) prior to and during shipping.

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Sendout Laboratory with any questions.

Laboratory

Sent to University of Texas Health Science Center at San Antonio, San Antonio, TX.

Performed

Mold: Set up on Monday.
Yeast: Set up on Tuesday.

Isolate needs to be received in the Laboratory by Friday.
Results available in 7 days.

Reference Range

By report.

Test Methodology

Mold: Macrobroth dilution.
Yeast: Microtiter dilution.

Interpretation

By report.

Clinical Utility

This is used to determine susceptibility of fungal isolates to selected antifungal therapies. This information is useful in selecting antimicrobial therapies.

CPT Codes

Varies.

Contacts

Last Updated

4/10/2021

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.