When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

BCR/ABL1 Tyrosine Kinase Inhibitor Resistance

T315I

Test Codes

Mayo: BAKDM, EPIC: LAB7586, Beaker:

Department

Send Outs

Instructions

Note: BCR/ABL fusion type must be provided for testing to be performed (p210, p190, p205, p230).

Specimen Collection Criteria

Collect: Whole blood or bone marrow in Lavender-top EDTA tubes.

Physician Office/Draw Specimen Preparation

Do not centrifuge or freeze. Maintain specimens in original tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 8mL whole blood or 4mL bone marrow, refrigerated (2-8°C or 36-46°F). (minimum whole blood 4 mL; minimum bone marrow 2 mL)

Rejection Criteria

Clotted.

Specimens not collected and processed as indicated.

In-Lab Processing

Do not centrifuge or freeze. Maintain specimens in original tube and refrigerate (2-8°C or 36-46°F).

Transport: 8mL whole blood or 4mL bone marrow, refrigerated (2-8°C or 36-46°F). (minimum whole blood 4 mL; minimum bone marrow 2 mL)

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 72 hours
Refrigerated (2-8°C or 36-46°F): 5 days
Frozen (-20°C/-4°F or below): unacceptable

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Laboratory

Sent to Mayo Clinic Laboratories in Rochester, MN.

Performed

Monday – Friday.
Results available in 6-8 days.

Reference Range

By report.

Test Methodology

Reverse Transcription – Polymerase Chain Reaction (RT-PCR) and DNA Sequencing.

Interpretation

By report.

Clinical Utility

This is the preferred initial test to identify the presence of acquired BCR/ABL1 mutations associated with TKI-resistance.

CPT Codes

81170