Culture, Legionella
Legionella Culture, Legionnaires Disease, Pontiac Fever, Pneumophila
Test Codes
EPIC: LAB5495
Department
Microbiology
Specimen Collection Criteria
Collect: One of the following specimen types, in a sterile, screw-capped collection container:
- Bronchial Brushings, Bronchial Washings, or Bronchoalveolar Lavage (BAL).
- Autopsy specimens from the chest cavity.
- Lung tissue.
- Thoracentesis fluid.
- Sputum (least preferred specimen type).
Physician Office/Draw Specimen Preparation
Deliver specimen to the Laboratory immediately after collection, refrigerated (2-8°C or 36-46°F), in a sterile, screw-capped collection container.
Preparation for Courier Transport
Transport: All specimen types, in a sterile, screw-capped collection container, refrigerated (2-8°C or 36-46°F).
Rejection Criteria
- Specimens submitted in saline.
- Specimens submitted in containers with formalin or that ever contained formalin.
- Specimens in non-sterile or leaking containers.
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): Unacceptable
Refrigerated (2-8°C or 36-46°F): 8 hours
Frozen (-20°C/-4°F or below): Unacceptable
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Dearborn Microbiology Laboratory
Taylor, Trenton and Wayne sent to Dearborn Microbiology Laboratory for testing.
Royal Oak Microbiology Laboratory
Farmington Hills, Grosse Pointe, and Troy sent to Royal Oak Microbiology Laboratory for testing.
Performed
Sunday – Saturday, 24 hours a day.
Final negative results available within one week.
Reference Range
No growth.
Test Methodology
Bacterial Culture.
Interpretation
Identification of Legionella spp. from respiratory specimens provides a definitive diagnosis of Legionnaires disease.
Clinical Utility
This test is useful for the diagnosis of Legionnaires disease.
Reference
Pasculle, A.W., and McDevitt, D., 2007. Legionella Cultures. Clinical Microbiology Procedure Manual, 3rd Edition. ASM Press. Washington, D.C., Section 3.11.4.
CPT Codes
87081
LOINC: 593-4
Contacts
Microbiology Laboratory – DBN
313-593-7921
Name: Microbiology Laboratory – DBN
Location:
Phone: 313-593-7921
Microbiology Laboratory – RO
248-551-8090
Name: Microbiology Laboratory – RO
Location:
Phone: 248-551-8090
Last Updated
8/27/2021
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.