When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Executive Health HDL LDL (Executive Health Service Only)

Executive Health Panel, EHS HDL/LDL

Test Codes

EPIC: LAB5045, EXHDL

Department

Chemistry

Instructions

It is recommended that the patient fast for 9-12 hours prior to the blood draw.

Specimen Collection Criteria

Collect: One Gold-top SST tube. (Minimum Whole Blood: 4.0 mL)

Rejection Criteria

Moderate to grossly hemolyzed specimens.

Red-top tubes with serum not separated from cells within two hours of collection.

In-Lab Processing

Let SST specimens clot 30-60 minutes. Centrifuge SST tubes or Microtainers® to separate serum from cells. Deliver immediately to the appropriate testing station.

Storage

Specimen Stability for Testing:

Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Royal Oak Automated Chemistry Laboratory

Performed

Sunday – Saturday, 24 hours a day.
Results available within 4 hours.

Reference Range

See specific assay for reference range.

This panel includes: Cholesterol, HDL Cholesterol, and Triglyceride.

Test Methodology

Enzymatic, Spectrophotometry.

Interpretation

See specific analytes for interpretations.

This panel includes: CholesterolHDL Cholesterol, and Triglyceride.

Clinical Utility

This panel aids in the evaluation of hyperlipidemia as an index of coronary artery disease.

Contacts

Last Updated

4/19/2021

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.