When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Flow Cytometry Crossmatch Transplantation

FCXM-Transplant, Flow Cytometry Crossmatch, Organ donor tissue typing, White cell crossmatch, Human leukocyte antigens, Crossmatch, Recipient Flow Cytometry Crossmatch

Test Codes

EPIC:  LAB6415

Department

Flow Cytometry

Instructions

This assay requires pre-scheduling with the Flow Cytometry Laboratory. Contact 248-551-8045 (extension 18045) to schedule testing.

Specimen Collection Criteria

Collect: Five 5 mL Green-top Sodium Heparin tubes on the DONOR and one Gold-top SST tube on the RECIPIENT.

Physician Office/Draw Specimen Preparation

Maintain specimens at room temperature (20-26°C or 68-78.8°F) and transport to the Laboratory immediately. Do not store specimens.

Preparation for Courier Transport

Transport: Heparin and SST tubes, at room temperature (20-26°C or 68-78.8°F).

Rejection Criteria

Any Green-top tubes sent on ice.

In-Lab Processing

Specimens should be analyzed immediately.

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): Specimens are tested immediately upon receipt.
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Royal Oak Flow Cytometry Laboratory

Performed

Monday – Thursday, at PRE-SCHEDULED TIMES.
Results available in 1-2 days.

Reference Range

Transplant
T-cell IgG: Less than 43.
B-cell IgG: Less than 57.

Test Methodology

Immunophenotyping by Multiparameter Flow Cytometry.

Interpretation

FCXM-Transplant: includes T-cell IgG in mean channel fluorescence intensity and B-cell IgG in mean channel fluorescence intensity.

Clinical Utility

This procedure can be used to identify IgG anti-lymphocyte antibodies for organ transplantation patients.

CPT Codes

88184, 88185, 88187.