Risperidone
Risperdal Level
Test Codes
Mayo: FRISP, EPIC: LAB6328, Beaker: XRISP
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One dark green-top sodium heparin tube.
Do not use Serum Separator Tubes.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.6 mL)
Rejection Criteria
Serum Separator (SST) tubes.
Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.6 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 72 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 180 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Mayo Clinic Laboratories in Rochester, MN. Forwarded to Medtox Laboratories.
Performed
Sunday – Saturday
Results available in 4-8 days.
Reference Range
By report.
Test Methodology
Quantitative Liquid Chromatography – Tandem Mass Spectrometry (LC-MS/MS).
CPT Codes
80342
LOINC: 9393-0
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/15/2021
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.