When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Acute Hepatitis Panel

Test Codes

EPIC: LAB5216, AHPT

Department

Chemistry

Instructions

Acute Hepatitis Panel includes:

Specimen Collection Criteria

Collect (preferred specimen): One Gold-top SST tube. (Minimum Whole Blood: 4.0 mL)
Also acceptable: One Lavender-top EDTA tube. (Minimum Whole Blood: 3.0 mL) 

Physician Office/Draw Specimen Preparation

  • Let SST specimens clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2–8°C or 36–46°F) the centrifuged SST tube within two hours of collection. (Minimum: 2.0 mL)
  • Centrifuge Lavender-top tube immediately to separate plasma from cells. Transfer plasma to a plastic transport tube and refrigerate (2–8°C or 36–46°F) within twelve hours of collection. (Minimum: 2.0 mL)

Preparation for Courier Transport

Transport: Centrifuged SST tube or plasma aliquot, refrigerated (2-8°C or 36-46°F). (Minimum: 2.0 mL serum or plasma)

Rejection Criteria

  • Hemolyzed specimens.
  • Severely lipemic specimens.
  • Specimens that have gross bacterial contamination.
  • Red-top tubes with serum not separated from cells within two hours of collection.
  • Lavender-top tubes with plasma not separated from cells within twelve hours of collection.

In-Lab Processing

Let SST specimens clot 30–60 minutes. Centrifuge SST, Lavender-top tubes, or Microtainers® to separate serum or plasma from cells. Deliver immediately to the appropriate testing station.

Storage

Specimen Stability for Testing:

Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20–26°C or 68–78.8°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20–25°C or 68–77°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20–26°C or 68–78.8°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days

Plasma Specimens (Aliquots)
Room Temperature (20–26°C or 68–78.8°F): 12 hours
Refrigerated (2–8°C or 36–46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days

Specimen Storage in Department Prior to Disposal:

Refrigerated (2–8°C or 36–46°F): 7 days

Laboratory

Dearborn Chemistry Laboratory
Farmington Hills Chemistry Laboratory
Royal Oak Automated Chemistry Laboratory 

Performed

Sunday – Saturday, 24 hours a day.
Results available within 24 hours of receipt in the Laboratory.

Reference Range

Hepatitis A Antibody (IgM):  Negative.
Hepatitis B Core Antibody (IgM):  Negative.
Hepatitis B Surface Antigen:  Negative.
Hepatitis C Antibody:  Negative.

Test Methodology

Chemiluminescent Immunoassay.

Clinical Utility

This panel is used in the differential diagnosis of hepatitis infections. See individual entries for more information:

Disease Reporting

This is a reportable infection and positive results will be reported to the Oakland County Health Department. For more information on reportable diseases, contact the epidemiology at 248-551-4040.

CPT Codes

80074

Contacts

Last Updated

4/15/2021

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.