Adenovirus, Quantitative PCR
Test Codes
ARUP: 2007192, EPIC: LAB7582, Beaker: XADVQ
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One Lavender-top EDTA tube.
Also acceptable: One gold-top SST tube.
Physician Office/Draw Specimen Preparation
Whole blood: Transport 1mL whole blood, refrigerated (2-8°C or 36-46°F).
Serum or plasma: Centrifuge to separate serum or plasma from cells. Transfer 1mL serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
- Frozen whole blood.
- Specimens not collected and processed as indicated.
In-Lab Processing
Whole blood: Transport 1mL whole blood, refrigerated (2-8°C or 36-46°F).
Serum or plasma: Centrifuge to separate serum or plasma from cells. Transfer 1mL serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 5 days
Frozen (-20°C/-4°F or below): 365 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT.
Performed
Sunday – Saturday
Results available in 2-5 days.
Reference Range
By report.
Test Methodology
Quantitative Real-Time Polymerase Chain Reaction.
Interpretation
The quantitative range of this assay is 3.0- 7.0 log copies/mL (1,000-10,000,000 copies/mL).
Clinical Utility
Detect and quantify adenovirus groups A-F. Diagnose adenovirus in patients. Monitor disease and/or response to therapy. A negative result (less than 3.0 log copies/mL or less than 1,000 copies/mL) does not rule out the presence of PCR inhibitors in the patient specimen or Adenovirus DNA concentrations below the level of detection of the assay. Inhibition may also lead to underestimation of viral quantitation.
No international standard is currently available for calibration of this assay. Caution should be taken when interpreting results generated by different assay methodologies.
CPT Codes
87799
LOINC: 31208-2, 49340-3, 64038-3, 39528-5
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/16/2021
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.