When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Amantadine Level

Symmetrel

Test Codes

ARUP #91195, EPIC: LAB6221, SOFT: XAMAN

Specimen Collection Criteria

Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One Dark Green-top Sodium Heparin or Lavender-top EDTA tube.

Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.

Physician Office/Draw Specimen Preparation

Centrifuge to separate serum or plasma from cells. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 2.0 mL serum or plasma at room temperature (2-8°C or 20-25°C). (Minimum: 0.7 mL)

Rejection Criteria

  • Serum Separator (SST) tubes.
  • Specimens not collected or processed as indicated.

In-Lab Processing

Centrifuge to separate serum or plasma from cells. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Transport: 2.0 mL serum or plasma at room temperature (2-8°C or 20-25°C). (Minimum: 0.7 mL) 

Storage

Ambient: 7 days
Refrigerated: 14 days
Frozen: 5 months

Laboratory

Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.

Performed

Varies.
Results available in 4-11 days.

Reference Range

By report.

Test Methodology

Quantitative Gas Chromatography.

Interpretation

By report.

Clinical Utility

This assay aids in the therapuetic monitoring of Amantadine hydrochloride (Symmetrelß), an anti-Parkinson and an antiviral drug. Symmetrelß is indicated for the prophylaxis and treatment of signs and symptoms of infection caused by various strains of influenza A virus it is also indicated in the treatment of parkinsonism and drug-induced extrapyramidal reactions.

CPT Codes

80375 (alternate code: G0480).
LOINC:  6-7

Contacts

Last Updated

6/29/2021