Carbamazepine Level
Tegretol, Carbamazepine Level, Serum
Test Codes
Antrim #17151, EPIC: LAB5380, CARBA
Department
Chemistry
Specimen Collection Criteria
Collect: One plain Red-top tube. (Minimum Whole Blood: 1.0 mL)
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to next dose.
Record the exact time of specimen collection on the tube or in the computer system.
Physician Office/Draw Specimen Preparation
Let specimens clot 30-60 minutes and refrigerate (2-8°C or 36-46°F) the collection tube within two hours of collection. (Minimum: 1.0 mL blood)
Preparation for Courier Transport
Transport: Collection tube, refrigerated (2-8°C or 36-46°F). (Minimum: 1.0 mL blood)
Rejection Criteria
Serum Separator (SST) tubes.
Severely lipemic or hemolyzed specimens.
In-Lab Processing
Let specimens clot 30-60 minutes. Centrifuge specimen to separate serum from cells. Deliver an aliquot of serum or the collection tube immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Collection Tubes
Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 3 months
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Dearborn Chemistry Laboratory
Royal Oak Chemistry Laboratory
Taylor Chemistry Laboratory
Wayne Chemistry Laboratory
Performed
Sunday – Saturday, 24 hours a day.
STAT results available within 1 hour of receipt in the Laboratory.
Routine results available within 24 hours.
Reference Range
Therapeutic Range: 6-12 mcg/mL.
Critical Range: Greater than 15 mcg/mL.
Test Methodology
Particle Enhanced Turbidimetric Inhibition Immunoassay.
Interpretation
Carbamazepine is capable of inducing its own clearance. It may be necessary to increase the maintenance dose after two weeks of continuous therapy.
Clinical Utility
Carbamazepine is an anticonvulsant drug used in the treatment of generalized and partial seizures. This assay aids in monitoring carbamazepine levels to ensure appropriate therapy.
CPT Codes
80156
LOINC: 3432-2, Last Dose Date 29742-4, Last Dose Time 29637-6
Contacts
Chemistry Laboratory – RO
248-551-8068
Name: Chemistry Laboratory – RO
Location:
Phone: 248-551-8068
Main Laboratory –WYN
734-467-4274
Name: Main Laboratory –WYN
Location:
Phone: 734-467-4274
Chemistry Laboratory – TYL
313-295-5360
Name: Chemistry Laboratory – TYL
Location:
Phone: 313-295-5360
Chemistry Laboratory – DBN
313-596-2196
Name: Chemistry Laboratory – DBN
Location:
Phone: 313-596-2196
Last Updated
7/19/2021
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.