When it comes to health, we can achieve something better. From discovering new ways to treat troubling conditions to prevention of diseases before they start, we believe progress should never stop.

Lab Test

Centromere Antibody

Anti-Centromere Antibody, Centromere Antibody, IgG

Test Codes

Antrim #30230, EPIC: LAB5753, SOFT: CENTR

Department

Special Chemistry

Specimen Collection Criteria

Collect: One Gold-top SST tube. (Minimum Whole Blood: 2.0 mL)

Physician Office/Draw Specimen Preparation

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection. (Minimum Serum: 0.5 mL)

Preparation for Courier Transport

Transport: Centrifuged collection tube, refrigerated (2-8 °C or 36-46 °F). (Minimum Serum: 0.5 mL)

Rejection Criteria

Plasma specimens. 

Severely hemolyzed, lipemic or icteric specimens.  

In-Lab Processing

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours. (Minimum Serum: 0.5 mL)

Storage

Specimen Stability for Testing:

Centrifuged SST Tubes and Microtainers® with Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 2 months

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Royal Oak Special Testing Laboratory

Performed

Monday – Friday.
Results available within 2 business days.

Reference Range

Negative: Less than 100 AU/mL.
Equivocal: 100-120 AU/mL.
Positive: Greater than 120 AU/mL.

Test Methodology

Multiplex Bead Immunoassay.

Clinical Utility

Centromere antibodies are present in 80-90% of individuals with CREST variant scleroderma. They are seen less frequently in Raynaud's phenomenon and other rheumatic diseases.

CPT Codes

83516
LOINC: 35272-4