Toxoplasma gondii by PCR
Test Codes
Mayo: PTOX, EPIC: LAB6165, Beaker: XTOGP
Department
Send Outs
Specimen Collection Criteria
Collect: Amniotic fluid, Cerebrospinal fluid (CSF), Ocular fluid, or biopsy tissue in a sterile container.
- Specimen source is required.
Physician Office/Draw Specimen Preparation
Fluid: Maintain specimens in a sterile container and refrigerate (2-8°C or 36-46°F).
Tissue: Place specimen in M4 Transport and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 0.5 mL amniotic fluid or CSF refrigerated (2-8°C or 36-46°F), or 0.3 mL ocular fluid refrigerated (2-8°C or 36-46°F), or tissue in M4 transport tube refrigerated (2-8°C or 36-46°F).
Rejection Criteria
Specimens not collected and processed as indicated.
In-Lab Processing
Transport: 0.5 mL amniotic fluid or CSF refrigerated (2-8°C or 36-46°F), or 0.3 mL ocular fluid refrigerated (2-8°C or 36-46°F), or tissue in M4 transport tube refrigerated (2-8°C or 36-46°F).
Storage
Specimen Stability for Testing:
Room temperature (20-26°C or 68-78.8°F): Unacceptable
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Mayo Clinic Laboratories in Rochester, MN.
Performed
Monday – Saturday
Results available within 2-5 days.
Reference Range
By report.
Test Methodology
Qualitative Polymerase Chain Reaction (PCR).
Interpretation
A negative result does not rule out the presence of PCR inhibitors in the patient specimen. Toxoplasma gondii DNA concentration below the level of detection by the assay.
Epidemiology
Toxoplasmosis occurs worldwide. Asymptomatic infections are common. Serological surveys show that 7 to 80% of various populations are infected. The developing fetus and immunocompromised patients are at risk for severe disease (1).
CPT Codes
87798
LOINC: 42626-2, 16279-2
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/20/2021
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.